| Product type designation |
CP 1612 A2 |
|
COMMUNICATION PROCESSOR CP 1612 A2 PCI-CARD (32 BIT; 3.3/5V UNIVERSAL KEYED) FOR CONNECT. TO IND. ETHERNET (10/100/1000MBIT/S) WITH RJ45 PORT VIA SOFTNET-S7 AND SOFTNET-PG SUPPORT FOR OPERATING SYSTEM SEE SIMATIC NET SW RELEASED FOR SIMATIC NET CD 2008 SP2 AND HIGHER |
| Transmission rate |
| Transfer rate |
|
| ● at the 1st interface |
10 ... 1000 Mbit/s |
| Interfaces |
| Number of electrical connections |
|
| ● at the 1st interface / acc. to Industrial Ethernet |
1 |
| Design of the electrical connection |
|
| ● at the 1st interface / acc. to Industrial Ethernet |
RJ45 port |
| Supply voltage, current consumption, power loss |
| Type of voltage / of the supply voltage |
DC |
| Supply voltage |
|
| ● 1 / from backplane bus |
5 V |
| ● 2 / from backplane bus |
12 V |
| Relative symmetrical tolerance / for DC |
|
| ● at 5 V |
5 % |
| ● at 12 V |
5 % |
| Consumed current |
|
| ● 1 / from backplane bus / for DC / maximum |
0.45 A |
| ● 2 / from backplane bus / for DC / maximum |
0.5 A |
| Active power loss |
3.65 W |
| Permitted ambient conditions |
| Ambient temperature |
|
| ● during operation |
0 ... 55 °C |
| ● during storage |
-10 ... +70 °C |
| ● during transport |
-10 ... +70 °C |
| Relative humidity / at 25 °C / without condensation / during operation / maximum |
95 % |
| Protection class IP |
IP00 |
| Design, dimensions and weight |
| Module format |
PCI |
| Width |
18 mm |
| Height |
59 mm |
| Depth |
140 mm |
| Net weight |
60 g |
| Number of plug-in cards of same design / plug-in / per PC station |
2 |
| Number of units / Note |
- |
| Performance data |
| Performance data / open communication |
| Software / for open communication / by means of SEND/RECEIVE / required |
Yes, SOFTNET-IE S7 (64 conn.) / SOFTNET-IE S7 Lean (8 conn.) |
| Number of possible connections / for open communication / by means of SEND/RECEIVE / maximum |
64 |
| Performance data / S7 communication |
| Software / for S7 communication / required |
Yes, SOFTNET-IE S7 (64 conn.) / SOFTNET-IE S7 Lean (8 conn.) |
| Number of possible connections / for S7/PG communication / maximum |
64 |
| Performance data / multi-protocol mode |
| Number of active connections / with multi-protocol mode |
64 |
| Number of configurable connections / per PC station |
207 |
| Performance data / PROFINET communication / as PN IO-Controller |
| Software / for PROFINET IO communication / required |
Yes, SOFTNET-IE PN IO |
| Number of PN IO devices / on PROFINET IO controller / usable / total |
64 |
| Number of PN IO IRT devices / on PROFINET IO controller / usable |
0 |
| Amount of data |
|
| ● as user data for input variables / as PROFINET IO controller / maximum |
4096 byte |
| ● as user data for input variables / as PROFINET IO controller / maximum |
4096 byte |
| ● as user data for input variables per PN IO device / as PROFINET IO controller / maximum |
1472 byte |
| ● as user data for output variables per PN IO device / as PROFINET IO controller / maximum |
1472 byte |
| Performance data / PROFINET CBA |
| Software / for PROFINET CBA communication / required |
Yes, PN CBA OPC server |
| Number of remote connection partners / with PROFINET CBA |
228 |
| Number of connections / with PROFINET CBA / total |
10000 |
| Product functions / management, configuration |
| Product function / MIB support |
No |
| Protocol / is supported |
|
| ● SNMP v1 |
Yes |
| ● SNMP v3 |
No |
| ● DCP |
Yes |
| ● LLDP |
Yes |
| Configuration software / for PROFINET CBA / required |
Yes, SIMATIC iMAP |
| Identification & maintenance function |
|
| ● I&M0 - device-specific information |
Yes |
| ● I&M1 – higher-level designation/location designation |
Yes |
| ● I&M2 - installation date |
No |
| ● I&M3 - comment |
No |
| ● I&M4 - signature |
No |
| Standards, specifications, approvals |
| Standard |
|
| ● for EMC |
2004/108/EC |
| ● for safety / from CSA and UL |
CAN/CSA C22.2 & UL 60950-1, UL 1950 |
| ● for emitted interference |
EN 61000-6-3, EN 61000-6-4 |
| ● for interference immunity |
EN 61000-6-1, EN 61000-6-2 |
| Certificate of suitability |
|
| ● CE marking |
Yes |
| ● C-Tick |
Yes |
| last modified: |
23.10.2014 |
Date 06.11.2014 |
Changes preserved © Copyright Siemens AG 2014 |